Talked to Dima about the NURI magnetometer network paper. His comments:
Talked to Dima about the NURI magnetometer network paper. His comments:


Line 10: Line 11:
** magnetometer has to be portable
** magnetometer has to be portable



=== Mx magnetometer sensitivity ===
Talked to Thad about a possibility to have a synchronously pumped scalar Mx magnetometer in the fMCG project. The advantages would be:
Talked to Thad about a possibility to have a synchronously pumped scalar Mx magnetometer in the fMCG project. The advantages would be:
* not having to cancel the field
* not having to cancel the field
Line 22: Line 25:


* Download the Mathematica notebook - [[File:ScalarMagnetometerParaffinCells.zip]]
* Download the Mathematica notebook - [[File:ScalarMagnetometerParaffinCells.zip]]

=== Coated cells sources ===

Asked around to find who could make some paraffin-coated cells for us. Dima's sources:

* Misha Balabas ($500-$700 per cell)
* Antonie Weis (sells 20x20mm cells that they no longer use)
* Wenhao's group (can make cells or fill cells)
* Precision Glass Blowing (had poor T1)

Asked Vitaliy Shutov from Frequency Standards Lab in FIAN, Troitsk. They have a setup that produces the cells in small (~10) batches. The cells are baked and sealed under vacuum and don't have stems. Cells can be filled with any gas mixture, but they don't make coating. The cells come in two sizes
* 8x15mm
* 5x3.5mm

Velichansky's group also has a stash of paraffin-coated 20x20mm cells.

Revision as of 18:53, 22 August 2016

August 2016

08/15/2016

NURI paper

Talked to Dima about the NURI magnetometer network paper. His comments:

  • The device section describes a solution without a problem. Add to the introducion:
    • need for the accurate timing
    • need to correlate signals from the different sensors
    • magnetometer has to be portable


Mx magnetometer sensitivity

Talked to Thad about a possibility to have a synchronously pumped scalar Mx magnetometer in the fMCG project. The advantages would be:

  • not having to cancel the field
  • no calibration
  • no 1/f electronic noise

Disadvantages:

  • spin-exchange relaxation
  • no vector sensitivity

Calculations for an Mx magnetometer built with a paraffin-coated 1cm3 cell show that it should be possible to get around 3 fT/sqrtHz per 1cm of the probe length.

Coated cells sources

Asked around to find who could make some paraffin-coated cells for us. Dima's sources:

  • Misha Balabas ($500-$700 per cell)
  • Antonie Weis (sells 20x20mm cells that they no longer use)
  • Wenhao's group (can make cells or fill cells)
  • Precision Glass Blowing (had poor T1)

Asked Vitaliy Shutov from Frequency Standards Lab in FIAN, Troitsk. They have a setup that produces the cells in small (~10) batches. The cells are baked and sealed under vacuum and don't have stems. Cells can be filled with any gas mixture, but they don't make coating. The cells come in two sizes

  • 8x15mm
  • 5x3.5mm

Velichansky's group also has a stash of paraffin-coated 20x20mm cells.