--[[User:Jmiles2|Jmiles2]] ([[User talk:Jmiles2|talk]]) 18:18, 9 June 2014 (CDT)
Need to find EIT again. Polarization might be an issue, need them to be opposite linearly polarized I think. Only using the Large FORT laser to trap atoms. Peaks look fine on the laser, and linewidth seems reasonable. I could try another diode, but I don't why I'm not seeing anything :(
 
<br />
--[[User:Jmiles2|Jmiles2]] ([[User talk:Jmiles2|talk]]) 14:17, 12 June 2014 (CDT)
EIT works, although the transfer should go to zero at high control powers, it seems to go back up at much higher powers, ~50mW control with 15 mW probe. beam sizes around 1mm. I can check my background better by looking at the two spots where I add together the pixels with no FORT. Subtracting these two should give me zero but there will be some small error in this.