- 15:0315:03, 25 August 2016 diff hist +202 FMCG/Experimental setup →Setting up computer and electronics
- 14:5914:59, 25 August 2016 diff hist +60 FMCG →Documentation
- 14:5414:54, 25 August 2016 diff hist +57 FMCG/Experimental setup No edit summary
- 14:5314:53, 25 August 2016 diff hist +149 FMCG/Experimental setup →Setting up computer and electronics
24 August 2016
- 21:3021:30, 24 August 2016 diff hist +40 FMCG/Magnetometer optimization →Probe Optimization current
- 21:2921:29, 24 August 2016 diff hist +183 FMCG/Magnetometer optimization No edit summary
- 21:2821:28, 24 August 2016 diff hist +445 FMCG/Magnetometer optimization No edit summary
- 20:5520:55, 24 August 2016 diff hist +2,763 FMCG/Magnetometer optimization No edit summary
- 20:2320:23, 24 August 2016 diff hist +320 N FMCG/Magnetometer optimization Created page with "The final part of magnetometer setup involves adjusting the pump and probe laser detunings to optimize the optical pumping and Faraday Rotation, respectively. This will assume..."
- 20:1920:19, 24 August 2016 diff hist +63 FMCG No edit summary
- 20:1720:17, 24 August 2016 diff hist +12 FMCG/Laser setup →Enabling the magnetometer current
- 20:1720:17, 24 August 2016 diff hist +88 FMCG/Laser setup →Enabling the magnetometer
- 20:1320:13, 24 August 2016 diff hist +138 FMCG/Field nulling No edit summary current
- 20:1220:12, 24 August 2016 diff hist −124 FMCG No edit summary
- 20:1120:11, 24 August 2016 diff hist −4 FMCG/Laser setup No edit summary
- 20:0920:09, 24 August 2016 diff hist +8,322 N FMCG/Laser setup Created page with "'''This section will cover everything up to the noise measurement, and will assume everything from the "Experimental Setup" procedure has been completed.''' =FPGA and Arduino..."
- 20:0920:09, 24 August 2016 diff hist +35 FMCG No edit summary
- 20:0820:08, 24 August 2016 diff hist −5,046 FMCG/Operating procedure No edit summary current
- 19:2919:29, 24 August 2016 diff hist +9,614 N FMCG/Field nulling Created page with "=Room Field Nulling= SERF regime demands very small residual magnetic fields, so any large fields remaining inside of the room must be "shimmed" or "nulled". One detector wil..."
- 19:2819:28, 24 August 2016 diff hist +39 FMCG No edit summary
- 19:2719:27, 24 August 2016 diff hist +1,916 FMCG/Field nulling and Optimization No edit summary current
- 19:1419:14, 24 August 2016 diff hist +2,470 FMCG/Field nulling and Optimization →Local Field Nulling
- 16:3816:38, 24 August 2016 diff hist +179 FMCG/Field nulling and Optimization No edit summary
- 16:2916:29, 24 August 2016 diff hist +5,049 N FMCG/Field nulling and Optimization Created page with "=Room Field Nulling= SERF regime demands very small residual magnetic fields, so any large fields remaining inside of the room must be "shimmed" or "nulled". One detector wil..."
- 16:2416:24, 24 August 2016 diff hist +72 FMCG →Documentation
- 16:2216:22, 24 August 2016 diff hist +1,712 FMCG/Operating procedure No edit summary
- 15:2015:20, 24 August 2016 diff hist +293 FMCG/Operating procedure No edit summary
- 14:5714:57, 24 August 2016 diff hist +1,319 FMCG/Operating procedure No edit summary
23 August 2016
- 22:1722:17, 23 August 2016 diff hist +526 FMCG/Operating procedure →Field Nulling
- 21:5321:53, 23 August 2016 diff hist +711 N File:WyllieSupply.jpg Board layout of a single-channel Wyllie current supply. The labeled parts are as follows (for the red switches, the switch pushed "up" is enabled, "down" is disabled): 1. DC input attenuator: [divide by 10, no attenuation, divide by 100] 2. Output res... current
- 21:4721:47, 23 August 2016 diff hist +401 FMCG/Operating procedure →Field Nulling
- 21:3321:33, 23 August 2016 diff hist +1,046 FMCG/Operating procedure No edit summary
- 21:1721:17, 23 August 2016 diff hist +1,444 FMCG/Operating procedure No edit summary
- 20:4720:47, 23 August 2016 diff hist +1,368 FMCG/Operating procedure No edit summary
- 20:2220:22, 23 August 2016 diff hist +613 FMCG/Operating procedure →Absorption Scan
- 19:3619:36, 23 August 2016 diff hist +1,083 FMCG/Operating procedure →Absorption Scan
- 19:1119:11, 23 August 2016 diff hist +573 FMCG/Operating procedure →Absorption Scan
- 18:4818:48, 23 August 2016 diff hist +299 FMCG/Operating procedure No edit summary
- 18:4518:45, 23 August 2016 diff hist +411 FMCG/Operating procedure No edit summary
- 18:3818:38, 23 August 2016 diff hist +196 FMCG/Experimental setup No edit summary
- 18:3618:36, 23 August 2016 diff hist +81 FMCG/Operating procedure No edit summary
- 18:3418:34, 23 August 2016 diff hist +195 FMCG/Operating procedure No edit summary
- 14:4114:41, 23 August 2016 diff hist 0 FMCG/Experimental setup No edit summary
- 14:4014:40, 23 August 2016 diff hist +444 FMCG/Experimental setup No edit summary
- 14:3514:35, 23 August 2016 diff hist +1,928 N FMCG/Operating procedure Created page with "'''This section will cover everything up to the noise measurement''' =FPGA and Arduino "Reset"= Both the FPGA and Arduino microcontroller tend to behave somewhat strangely af..."
22 August 2016
- 22:0522:05, 22 August 2016 diff hist −4 FMCG/Experimental setup No edit summary
- 20:3720:37, 22 August 2016 diff hist −17 FMCG/Experimental setup No edit summary
- 20:1820:18, 22 August 2016 diff hist +168 FMCG/Experimental setup →Initial Setup
- 17:5417:54, 22 August 2016 diff hist +4,787 FMCG/Experimental setup →Initial Setup
- 15:0215:02, 22 August 2016 diff hist +34 N File:ArrayOnBed.jpg Photo of array sitting on the bed. current