David Notebook: Difference between revisions

Jump to navigation Jump to search
Deniz can calculate the maximum theoretical conversion efficiency of 780 if we know the amount of 1064 and 1555 in the cavity. I separated the beams with a prism and measured 5 mW maximum of 1064 when locking and 14 mW maximum of 1555. The prism (Thorlabs PS853) has a listed transmittance of ~28% for both 1064 and 1555, so exiting the cavity there should be 17.9 mW of 1064 and 50 mW of 1555.
 
The cavity mirror transmits 32 ppm and 38 ppm of 1064 and 1555 respectively, so that puts the powers at 559 W and 1316 W inside the cavity. The beam sizes were both about 1700 μm 30 cm from the cavity, so theirthe 1064 and 1555 intensities are approximately:
 
<math> 770 </math> <math> MW/cm^2 </math> and <math> 1810 </math> <math> MW/cm^2 </math>