Jared lab notebook: Difference between revisions

Jump to navigation Jump to search
no edit summary
No edit summary
No edit summary
--[[User:Jmiles2|Jmiles2]] ([[User talk:Jmiles2|talk]]) 18:01, 16 June 2014 (CDT)
I can get EIT on both beams, and they both do basically the same thing, the curves aren't exact, but they never have been. The second EIT pulse looks slightly different than the first but the most transfer still occurs around 3mW. I think the standing wave is working but it isn't consistent. There is a pattern there, but it's much noiser than ones that I have seen before.
 
<br />
--[[User:Jmiles2|Jmiles2]] ([[User talk:Jmiles2|talk]]) 12:42, 20 June 2014 (CDT)
Can't get a good standing wave pattern, even though EIT curves look good. I think it might be something with the FORT. It's possibly too inconsistent to see the small change (~20%) I need to see in the standing wave patter. I looked at scans of the Large FORT yesterday and it looks like the signal was oscillating much more than it was when I did EIT before with the D1 line with the 850 nm FORT. I'm going to try to get the 1064 TA FORT working so I can see if the signal from those FORT atoms is more stable.