Differences between revisions 48 and 101 (spanning 53 versions)
Revision 48 as of 2019-02-21 15:27:08
Size: 3533
Editor: ChadSeys
Comment:
Revision 101 as of 2024-08-29 13:23:47
Size: 6010
Editor: ChadSeys
Comment:
Deletions are marked like this. Additions are marked like this.
Line 9: Line 9:
  * ''set puppet service to Automatic (Delayed Start) and under Recovery tab set recovery options to attempt restart twice with 5 minute delay. (The puppet service doesn't start successfully on Windows 10 and the !OptiPlex 7020). ''
Line 17: Line 18:
 * ''Acrobat / Edge ''- open PDF from web as a test
 * ''Java ''
 * ''Acrobat / Edge''
  * open PDF from web as a test
 * ''Chromium'' - Canvas not compatible with Internet Explorer
  * ''uBlock Origin'' extension is prompted to be installed by default. Need to open Chromium once as student user to be prompted.
 * ''Java''
Line 21: Line 25:
 * ''Flash ''
Line 28: Line 31:
  * change ntp server to time.nist.gov (often time.windows.com does not work).
  * Turn on Microsoft Update in Windows Update (updates Office also).
  * Turn on 'recieve updates for other Microsoft products'. (updates Office also).
Line 31: Line 33:
  * excel on desktop and pinned to taskbar
  * auto login as student https://technet.microsoft.com/en-us/library/ee872306.aspx
  * Excel on desktop and pinned to taskbar
  * Chromium pinned to taskbar
  * Internet Explorer pinned to taskbar (for 109 labs Java applet)
  * 'student' standard user, 'iphysics' administrator, 'teacher' administrator
   * passwords in psafe
   * ''password setting for 'student' puppetized''
  * auto login as student (last login before capturing image is as password-less student user)
  * turn on remote desktop and add student allowed list. Administrators are automatically on the allowed list. Only accounts with passwords are allowed to log in.
  * ''Tektronix OpenChoice Desktop (623 uses it)''
   * Preferences -> VISA -> Search Criteria -> turn on USB, turn off GBIP, LAN
   * Plug in an oscilloscope and make OpenChoice Desktop the default action for Autoplay
  * Associate Windows Photo Viewer with .bmp files. Open an .bmp image file and select the prompt.
Line 36: Line 48:
 * Excel shortcut pinned to taskbar
Line 39: Line 50:
 * ''Tektronix OpenChoice Desktop''
  * Preferences -> VISA -> turn on USB, turn off GBIP, LAN
  * turn off update notifications (if possible)
Line 44: Line 54:
 * ''QTIPlot''  * QTIPlot
Line 46: Line 56:
 * ''LabView''
  * We have a license file from NI for Labview 2017 which is locked to a Volume ID stored in psafe. So compare Volume ID on drive to that in psafe and change to match if needed. (Google how to change Volume ID to match if needed.)
  * ''activate license following'' [[http://digital.ni.com/public.nsf/allkb/CEF3043068981186862578090074BF31|these]] ''instructions.''
 * [[http://sine.ni.com/nips/cds/view/p/lang/en/nid/10181|NI-DAQmx]]
Line 51: Line 57:
 * ''Tektronix OpenChoice Desktop''
  * Preferences -> VISA -> turn on USB, turn off GBIP, LAN

 * 307/308 computers:
  * ''[[http://www.spectrumtechniques.com/products/components/|UCS30 driver]] (bitness of driver matches OS, i.e. 64-bit)''
 * Canon Remote Capture (for 109)
  * Copy the Digital Camera Solution Disk 29.0 from the instructional lab installers folder. Copy to local drive and run Setup.exe . Install just ZoomBrowser FX. Reboot.
  * Plug in a PowerShot G7 camera. This associates the auto-launch of CameraWindow. (Test and fix until CameraWindow opens when camera is plugged in / turned on.)
 * ''!OpticStudio''
 * ''Altera Quartus II Web Edition, Programmer, SignalTap, v13'' (for 623)
 * [[ftp://ftp.sbig.com/pub/SetupDriverChecker64.exe|SBIG 64-bit driver checker]] Install the checker, than run an update to install the drivers. (for 307/308/407/507 USB CCD)
 * [[ftp://ftp.sbig.com/pub/InstOps.exe|CCDOps]] Install the SBIG checker, than run an update to install the drivers. (for 307/308/407/507 USB CCD)
 * ''[[http://www.spectrumtechniques.com/products/components/|UCS30 driver]] (bitness of driver matches OS, i.e. 64-bit)'' (for 307/308)
 * ''GIMP / Inkscape / Winfig'' (requested by Winokur for marking up images 307/308)
 * !LabView 2017 instructions
  * We have a license file from NI for Labview 2017 which is locked to a Volume ID. See [[http://digital.ni.com/public.nsf/allkb/CEF3043068981186862578090074BF31|these]] instructions for how this was accomplished. In summary:
   * Change VolumeID to match that stored in psafe labview_mass_deploy.
   * ''Install LabVIEW'' (puppet does it)
   * update using National Instruments Package Manager
   * visit http://ni.com/activate
   * Enter serial number and Computer ID (psafe labview_mass_deploy) to get Activation Codes
   * Enter activation codes in to National Instruments License Manager. (Do not log in, close that window.)
  * ''activate license following deployment ''(see notes in puppet for how to reconfigure for new versions/changed names.'')''
 * ''[[http://sine.ni.com/nips/cds/view/p/lang/en/nid/10181|NI-DAQmx]]''
 * ''Oceanview'' (1.6.7) 109, 307/308
  * Run once to allow through firewall.
  * It is nice to show the visible spectrum in the graph. Right-click on the graph, "Graph layer options", "Visible Spectrum" tab, "Show visible spectrum" radio button.
  * The 'lite' version suffices
Line 59: Line 83:
  * Canon Remote Capture (at the moment installed on Advanced Lab base image)
   * Copy the Digital Camera Solution Disk 29.0 from the instructional lab installers folder. Copy to local drive and run Setup.exe . Install just ZoomBrowser FX. Reboot.
Line 63: Line 85:
  * TODO : Origin - as of Spring 2021
Line 68: Line 91:
   * ''Nanosurf Easyscan''
Line 70: Line 94:
  * NI Multisim
  * ''Altera Quartus II Web Edition, Programmer, SignalTap, v13'' (at the moment installed on Advanced Lab base image)
  * NI Multisim (Student Edition 12.0.1). See technote for serial number, etc.
  * ''DEO-nano'' (installed on network drive)
  * install driver for board. Plug the board in, find the device in Device Manager, and install driver by recusively scanning c:\altera.
Line 80: Line 105:
 * ''Cisco AMP''
  * Log in to student
  • These are the things to watch for when creating a new lab image. You should be able to answer each of these yes or okay. Details will vary a little between intro and advanced labs.

Italicized items have been "puppetized".

Checklist for image:

  • Tivoli Endpoint Management Client
  • Puppet client
    • set puppet service to Automatic (Delayed Start) and under Recovery tab set recovery options to attempt restart twice with 5 minute delay. (The puppet service doesn't start successfully on Windows 10 and the OptiPlex 7020).

  • 7-zip (can unpack Office .iso file)

  • Office (Word, Excel)
    • run excel as administrator user
    • run excel as student user (maybe not needed?)
    • ensure activated

      • open Command Prompt as Administrator
      • then run cscript "C:\Program Files\Microsoft Office\Office15\ospp.vbs" /act 

    • ensure analysis toolpak enabled in excel as student user
  • Acrobat / Edge

    • open PDF from web as a test
  • Chromium - Canvas not compatible with Internet Explorer

    • uBlock Origin extension is prompted to be installed by default. Need to open Chromium once as student user to be prompted.

  • Java

    • change java settings to "do not check" for updates
    • Run all applets as student user and choose the "do not bother me" options Java Applets

  • Matlab (network server https://www.mathworks.com/matlabcentral/answers/106003-how-do-i-install-a-matlab-client-for-a-network-license?s_tid=gn_loc_drop)

  • Mathematica

  • set browsers' homepage to current semester course reference page

  • Windows tasks
    • ensure activated

    • change powersave to never sleep/hibernate, but turn off display after 15 minutes.

    • Turn on 'recieve updates for other Microsoft products'. (updates Office also).
    • remove excess printers (like fax)
    • Excel on desktop and pinned to taskbar
    • Chromium pinned to taskbar
    • Internet Explorer pinned to taskbar (for 109 labs Java applet)
    • 'student' standard user, 'iphysics' administrator, 'teacher' administrator
      • passwords in psafe
      • password setting for 'student' puppetized

    • auto login as student (last login before capturing image is as password-less student user)
    • turn on remote desktop and add student allowed list. Administrators are automatically on the allowed list. Only accounts with passwords are allowed to log in.
    • Tektronix OpenChoice Desktop (623 uses it)

      • Preferences -> VISA -> Search Criteria -> turn on USB, turn off GBIP, LAN

      • Plug in an oscilloscope and make OpenChoice Desktop the default action for Autoplay

    • Associate Windows Photo Viewer with .bmp files. Open an .bmp image file and select the prompt.

Intro labs programs:

  • PASCO Capstone

    • PASCO Capstone on desktop and pinned to taskbar
    • turn off update notifications (if possible)

Advanced labs programs:

  • QTIPlot
  • CASSY Lab
  • X-Ray Apparatus
  • Canon Remote Capture (for 109)
    • Copy the Digital Camera Solution Disk 29.0 from the instructional lab installers folder. Copy to local drive and run Setup.exe . Install just ZoomBrowser FX. Reboot.

    • Plug in a PowerShot G7 camera. This associates the auto-launch of CameraWindow. (Test and fix until CameraWindow opens when camera is plugged in / turned on.)

  • OpticStudio

  • Altera Quartus II Web Edition, Programmer, SignalTap, v13 (for 623)

  • SBIG 64-bit driver checker Install the checker, than run an update to install the drivers. (for 307/308/407/507 USB CCD)

  • CCDOps Install the SBIG checker, than run an update to install the drivers. (for 307/308/407/507 USB CCD)

  • UCS30 driver (bitness of driver matches OS, i.e. 64-bit) (for 307/308)

  • GIMP / Inkscape / Winfig (requested by Winokur for marking up images 307/308)

  • LabView 2017 instructions

    • We have a license file from NI for Labview 2017 which is locked to a Volume ID. See these instructions for how this was accomplished. In summary:

      • Change VolumeID to match that stored in psafe labview_mass_deploy.
      • Install LabVIEW (puppet does it)

      • update using National Instruments Package Manager
      • visit http://ni.com/activate

      • Enter serial number and Computer ID (psafe labview_mass_deploy) to get Activation Codes
      • Enter activation codes in to National Instruments License Manager. (Do not log in, close that window.)
    • activate license following deployment (see notes in puppet for how to reconfigure for new versions/changed names.)

  • NI-DAQmx

  • Oceanview (1.6.7) 109, 307/308

    • Run once to allow through firewall.
    • It is nice to show the visible spectrum in the graph. Right-click on the graph, "Graph layer options", "Visible Spectrum" tab, "Show visible spectrum" radio button.
    • The 'lite' version suffices
  • 109 computers:
    • PASCO Capstone

  • 407 computers:
    • TODO : Origin - as of Spring 2021
    • Install Advanced Image, then install:
      • NI-VISA with .NET options

      • Thermal Noise

      • Ramsauer

      • Oscilloscope Setup

      • Nanosurf Easyscan

  • 623 computers:
    • NI Multisim (Student Edition 12.0.1). See technote for serial number, etc.
    • DEO-nano (installed on network drive)

    • install driver for board. Plug the board in, find the device in Device Manager, and install driver by recusively scanning c:\altera.

Final cleanup

  • clear browsing history of Student

  • delete Downloads of Student

  • empty trash of Student

  • run Disk Cleanup
  • defragment disk
  • Cisco AMP

    • Log in to student


CategoryComputing