Size: 1257
Comment:
|
← Revision 18 as of 2019-10-29 16:24:44 ⇥
Size: 1886
Comment:
|
Deletions are marked like this. | Additions are marked like this. |
Line 1: | Line 1: |
## page was renamed from H-1-200 | |
Line 6: | Line 7: |
==== Quantity: 24 ==== | |
Line 8: | Line 10: |
* Lab Table Setup | |
Line 9: | Line 12: |
[[attachment:H1 Setup.png|{{attachment:H1 Setup.png|attachment:H1 Setup.png|width="500 height=323"}}]] | |
Line 10: | Line 14: |
* Operation | |
Line 11: | Line 16: |
<<Thumbnail(H-1-200.png,500,323)>> | [[attachment:H1 Operation.png|{{attachment:H1 Operation.png|attachment:H1 Operation.png|width="500 height=323"}}]] |
Line 13: | Line 19: |
* 1 PC & Interface * 1 [[4325-3#PASCO_Pressure_Sensor|PASCO Bracket-Mounted Pressure Sensor]] |
* 1 PASCO 850 Universal Interface * 1 [[4325-3#PASCO_Pressure_Sensor|PASCO Bracket-Mounted Pressure Sensor]] (Plug sensor into Channel A) |
Line 17: | Line 23: |
* 1 Dewar Flask ([[4325-2#Large_DEWAR_Flask|Large]], [[4325-2#Small_DEWAR_Flask|Small]]) | * 1 [[4325-2#Small_DEWAR_Flask|Dewar Flask]] |
Line 19: | Line 25: |
* 1 [[4325-1#PASCO_Steam_Generator|PASCO Steam Generator]] * 1 [[4325-3#Fluke_Digital_Thermometer|Fluke Digital Thermometer]] * w/ [[4325-3#Temperature_Probe|Probe]] (Long, Short) * 1 [[4325-3#Plastic_Syringe|60cc Plastic Syringe]] |
* 1 [[4325-1#PASCO_Steam_Generator|PASCO Steam Generator]] (Fill to 1" of top with DI water from 4329) * 1 [[4325-3#Fluke_Digital_Thermometer|Fluke Digital Thermometer]] (Check batteries and check for reasonable room temperature) * w/ [[4325-3#Temperature_Probe_Long.2BAC8-Short|Probe]] (Long, Short) * 1 [[4325-3#Plastic_Syringe|60cm^3 Plastic Syringe]] (Make sure measurement markings are readable) |
Line 26: | Line 33: |
* 1 Sponge | |
Line 30: | Line 36: |
* Plug pressure sensor in to Pasco interface * Fill steam generators with de-ionized water (to within 1" of rim) * Check that thermometer and probe give sensible readings (room temperature) |
|
Line 33: | Line 42: |
Line 36: | Line 46: |
[[LiquidNitrogenFilling| Liquid Nitrogen Filling Procedure]] |
[[LiquidNitrogenFilling|Liquid Nitrogen Filling Procedure]] |
H-1: The Ideal Gas Law & Absolute Zero
Quantity: 24
- Lab Table Setup
- Operation
Experiment Contents
- 1 PASCO 850 Universal Interface
1 PASCO Bracket-Mounted Pressure Sensor (Plug sensor into Channel A)
w/ 1/4" T-Stand
1 PASCO Steam Generator (Fill to 1" of top with DI water from 4329)
1 Fluke Digital Thermometer (Check batteries and check for reasonable room temperature)
w/ Probe (Long, Short)
1 60cm^3 Plastic Syringe (Make sure measurement markings are readable)
Also
- 1 100L Dewar Liquid N2 (In 4329)
- 1 4L Dewar for Lab Room
Check
- Plug pressure sensor in to Pasco interface
- Fill steam generators with de-ionized water (to within 1" of rim)
- Check that thermometer and probe give sensible readings (room temperature)
- Computer Set-Up (PC, Interface On Before Computer, Sensors Work)
100L Dewar & Ice Chest Filled (In 4329)
- Extra Paper Towels