  * Lab Table Setup
[[attachment:H1 Setup.png|{{attachment:H1 Setup.png||width=500 height=323}}]]
 * Lab Table Setup

[[attachment:H1 Setup.png|{{attachment:H1 Setup.png|attachment:H1 Setup.png|width="500 height=323"}}]]
Line 12: Line 15:
[[attachment:H1 Operation.png|{{attachment:H1 Operation.png||width=500 height=323}}]] 
[[attachment:H1 Operation.png|{{attachment:H1 Operation.png|attachment:H1 Operation.png|width="500 height=323"}}]]
Line 15: Line 19:
 * 1 PC & Interface
 * 1 [[4325-3#PASCO_Pressure_Sensor|PASCO Bracket-Mounted Pressure Sensor]]
 * 1 PASCO 850 Universal Interface
 * 1 [[4325-3#PASCO_Pressure_Sensor|PASCO Bracket-Mounted Pressure Sensor]] (Plug sensor into Channel A)
Line 21: Line 25:
 * 1 [[4325-1#PASCO_Steam_Generator|PASCO Steam Generator]]
 * 1 [[4325-3#Fluke_Digital_Thermometer|Fluke Digital Thermometer]]
 * 1 [[4325-1#PASCO_Steam_Generator|PASCO Steam Generator]] (Fill to 1" of top with DI water from 4329)
 * 1 [[4325-3#Fluke_Digital_Thermometer|Fluke Digital Thermometer]] (Check batteries and check for reasonable room temperature)
Line 24: Line 28:
 * 1 [[4325-3#Plastic_Syringe|60cc Plastic Syringe]]  * 1 [[4325-3#Plastic_Syringe|60cm^3 Plastic Syringe]] (Make sure measurement markings are readable)
Line 28: Line 33:
 * 1 Sponge
Line 32: Line 36:
 * Plug pressure sensor in to Pasco interface
 * Fill steam generators with de-ionized water (to within 1" of rim)
 * Check that thermometer and probe give sensible readings (room temperature)
Line 35: Line 42:
Line 38: Line 46:


[[LiquidNitrogenFilling| Liquid Nitrogen Filling Procedure]]
[[LiquidNitrogenFilling|Liquid Nitrogen Filling Procedure]]

H-1: The Ideal Gas Law & Absolute Zero

Quantity: 24

  • Lab Table Setup

attachment:H1 Setup.png

  • Operation

attachment:H1 Operation.png

Experiment Contents

Also

Check

  • Plug pressure sensor in to Pasco interface
  • Fill steam generators with de-ionized water (to within 1" of rim)
  • Check that thermometer and probe give sensible readings (room temperature)
  • Computer Set-Up (PC, Interface On Before Computer, Sensors Work)
  • 100L Dewar & Ice Chest Filled (In 4329)

  • Extra Paper Towels


200 Level Index

Liquid Nitrogen Filling Procedure