Differences between revisions 8 and 21 (spanning 13 versions)
Revision 8 as of 2012-08-01 16:37:34
Size: 1102
Editor: dhcp-105
Comment:
Revision 21 as of 2014-07-31 19:00:14
Size: 1841
Editor: RyanPease
Comment:
Deletions are marked like this. Additions are marked like this.
Line 8: Line 8:
<<Thumbnail(E-6-200.png,500,138)>> [[attachment:E-6-200.png|{{attachment:E-6-200.png|attachment:E-6-200.png|width="500 height=138"}}]]
Line 11: Line 11:
 * 1 [[3323 Shelf-2#Leader_Oscilloscope|Oscilloscope]]
 * 1 [[3323-2#Kruhn-Hite_Function_Generators|Function Generator]] (Krohn-Hite, Pasco)
 * 1 [[3323-1#Multimeter|Keithley 175 Digital Multimeter]]
 * 1 [[3323-1#Leader_Oscilloscope|Oscilloscope]]
  * w/ 2 [[Hanging Oscilliscope Probes#BNC to Alligator Cables|Oscilloscope Probe]]
 * 1 [[3323-1#Kruhn-Hite_Function_Generators|Function Generator]] (Krohn-Hite, Pasco)
 * 1 [[3323-2#FlukeMultimeter|Fluke 115 Handheld Multimeter]]
  * w/[[Hanging PASCO Voltage Sensors#Fluke_Multimeter_Sensor|Fluke Multimeter Probe Set]]
 * 1 [[3323-3#BNC to Alligator Cables|BNC to Alligator Cable]]
Line 16: Line 19:
 * 1 [[4327-2#UW_Timer|UW Timer]] (Include Only If Using Krohn-Hite Type Function Generator)
Line 22: Line 24:
 * [[3323-9#Plug_Board_Kit|Plug Board Kit]] (29 Items)  * [[3323-9#Plug_Board_Kit|Plug Board Kit]] (30 Items)
Line 25: Line 27:
  * Capacitor Set (47nf, 1μf)   * Capacitor Set (47nF, 1μF, 0.47μF)
Line 27: Line 29:
  * Inductor (1 Hy)   * Inductor (1 H)
Line 34: Line 36:
=== Troubleshooting ===
If the output of the differential amplifier is unstable, verify that all E-6 equipment is plugged into the Tripp Lite power strip, which is located adjacent to the lab table (see photo below), and the Tripp Lite power strip is plugged into the wall. No E-6 equipment should be plugged into the power strip on the back of the computer cart, which has a dubious ground (as of 3/10/14).

[[attachment:TrippLite.png|{{attachment:TrippLite.png|attachment:TrippLite.png|width="500 height=138"}}]]

E-6: Cathode Ray Oscilloscope And Differential Amplifier

Quantity: 39

attachment:E-6-200.png

Experiment Contents

Also
  • 1 Oscilloscope Manual

Check

  • Plug Board Kit (30 Items)

    • Resistor Set (1kΩ, 2.2kΩ, 3.3kΩ, 4.7kΩ, 10kΩ, 20kΩ, 100kΩ, 10MΩ)
    • 8 Bridge Plugs
    • Capacitor Set (47nF, 1μF, 0.47μF)
    • Diode
    • Inductor (1 H)
    • SPDT Switch
    • Variable Resistor (1k)
    • Transistor (2N1480)
    • Differential Amplifier
    • Adapter Set (2 Pomona 1269, 2 Pomona 1296, 1 BNC 'T')

Troubleshooting

If the output of the differential amplifier is unstable, verify that all E-6 equipment is plugged into the Tripp Lite power strip, which is located adjacent to the lab table (see photo below), and the Tripp Lite power strip is plugged into the wall. No E-6 equipment should be plugged into the power strip on the back of the computer cart, which has a dubious ground (as of 3/10/14).

attachment:TrippLite.png


200 Level Index

Home

il: E-206 (last edited 2018-06-04 18:51:12 by BrettUnks)