=== E-6: Cathode Ray Oscilloscope And Differential Amplifier === | === E-6: Oscilloscopes and RC Decay === ==== Quantity: 39 ==== |
Line 7: | Line 9: |
{{attachment:E-6-200.png|E-6|width="500"}} | [[attachment:E-6-200.png|{{attachment:E-6-200.jpg|attachment:E-6-200.jpg|width="500 height=138"}}]] |
Line 10: | Line 12: |
* 1 Oscilloscope * 1 Function Generator (Krohn-Hite, Pasco) * 1 Keithley 175 Digital Multimeter * 1 Plug Board * w/Kit * 1 UW Timer (Include Only If Using Krohn-Hite Type Function Generator) ===== Also ===== * 1 Oscilloscope Manual |
* 1 [[3323-1#Leader_Oscilloscope|Oscilloscope]] * w/ 2 [[Hanging Oscilloscope Probes#BNC_to_Alligator_Cables|Oscilloscope Probes]] * 1 Oscilloscope Manual * 1 [[3323-1#Kruhn-Hite_Function_Generators|Function Generator]] * 1 [[3323-2#FlukeMultimeter|Fluke 115 Handheld Multimeter]] * w/[[Hanging PASCO Voltage Sensors#Fluke_Multimeter_Sensor|Fluke Multimeter Probe Set]] * 2 [[3323-3#BNC_to_Alligator_Cables|BNC to Alligator Cable]] * 1 [[3323-10#Plug_Board|Plug Board]] * w/[[3323-9#Plug_Board_Kit|Kit]] |
Line 21: | Line 23: |
* Plug Board Kit (29 Items) * Resistor Set (1kΩ, 2.2kΩ, 3.3kΩ, 4.7kΩ, 10kΩ, 20kΩ, 100kΩ, 10MΩ) |
* [[3323-9#Plug_Board_Kit|Plug Board Kit]] (30 Items) * Resistor Set (100Ω, 200Ω, 400Ω, 1kΩ, 2.2kΩ, 3.3kΩ, 4.7kΩ, 10kΩ, 20kΩ, 100kΩ, 10MΩ) |
Line 24: | Line 26: |
* Capacitor Set (47nf, 1μf) | * Capacitor Set (47nF, 1μF, 0.47μF) |
Line 26: | Line 28: |
* Inductor (1 Hy) | * Inductor (1 H) |
Line 33: | Line 35: |
=== Troubleshooting === If the output of the differential amplifier is unstable, verify that all E-6 equipment is plugged into the Tripp Lite power strip, which is located adjacent to the lab table (see photo below), and the Tripp Lite power strip is plugged into the wall. No E-6 equipment should be plugged into the power strip on the back of the computer cart, which has a dubious ground (as of 3/10/14). [[attachment:TrippLite.png|{{attachment:TrippLite.png|attachment:TrippLite.png|width="500 height=138"}}]] |
|
Line 35: | Line 42: |
[[Home]] |
E-6: Oscilloscopes and RC Decay
Quantity: 39
Experiment Contents
w/ 2 Oscilloscope Probes
- 1 Oscilloscope Manual
w/Kit
Check
Plug Board Kit (30 Items)
- Resistor Set (100Ω, 200Ω, 400Ω, 1kΩ, 2.2kΩ, 3.3kΩ, 4.7kΩ, 10kΩ, 20kΩ, 100kΩ, 10MΩ)
- 8 Bridge Plugs
- Capacitor Set (47nF, 1μF, 0.47μF)
- Diode
- Inductor (1 H)
- SPDT Switch
- Variable Resistor (1k)
- Transistor (2N1480)
- Differential Amplifier
- Adapter Set (2 Pomona 1269, 2 Pomona 1296, 1 BNC 'T')
Troubleshooting
If the output of the differential amplifier is unstable, verify that all E-6 equipment is plugged into the Tripp Lite power strip, which is located adjacent to the lab table (see photo below), and the Tripp Lite power strip is plugged into the wall. No E-6 equipment should be plugged into the power strip on the back of the computer cart, which has a dubious ground (as of 3/10/14).