Differences between revisions 14 and 27 (spanning 13 versions)
Revision 14 as of 2014-03-10 21:39:57
Size: 1593
Editor: JimReardon
Comment:
Revision 27 as of 2018-01-05 15:18:39
Size: 1878
Editor: BrettUnks
Comment:
Deletions are marked like this. Additions are marked like this.
Line 1: Line 1:
## page was renamed from E-6-200
Line 8: Line 9:
[[attachment:E-6-200.png|{{attachment:E-6-200.png|attachment:E-6-200.png|width="500 height=138"}}]] [[attachment:E-6-200.png|{{attachment:E-6-200.jpg|attachment:E-6-200.jpg|width="500 height=138"}}]]
Line 11: Line 12:
 * 1 [[3323 Shelf-2#Leader_Oscilloscope|Oscilloscope]]
 * 1 [[3323-2#Kruhn-Hite_Function_Generators|Function Generator]] (Krohn-Hite, Pasco)
 * 1 [[3323-1
#FlukeMultimeter|Fluke 115 Handheld Multimeter]]
  * w/[[Hanging PASCO Voltage Sensors#Fluke_Multimeter_Sensor|Hanging PASCO Voltage Sensors#Fluke Multimeter Sensor]]
 * 1 [[3323-1#Leader_Oscilloscope|Oscilloscope]]
  * w/ 2 [[Hanging Oscilloscope Probes#BNC to Alligator Cables|Oscilloscope Probes]]
 
* 1 [[3323-1#Kruhn-Hite_Function_Generators|Function Generator]]
 * 1 [[3323
-2#FlukeMultimeter|Fluke 115 Handheld Multimeter]]
  * w/[[Hanging PASCO Voltage Sensors#Fluke_Multimeter_Sensor|Fluke Multimeter Probe Set]]
 * 2 [[3323-3#BNC to
Alligator Cables|BNC to Alligator Cable]]
Line 17: Line 20:
 * 1 [[4327-2#UW_Timer|UW Timer]] (Include Only If Using Krohn-Hite Type Function Generator)
Line 24: Line 26:
  * Resistor Set (1kΩ, 2.2kΩ, 3.3kΩ, 4.7kΩ, 10kΩ, 20kΩ, 100kΩ, 10MΩ)   * Resistor Set (100Ω, 200Ω, 400Ω, 1kΩ, 2.2kΩ, 3.3kΩ, 4.7kΩ, 10kΩ, 20kΩ, 100kΩ, 10MΩ)
Line 36: Line 38:
If the output of the differential amplifier is unstable, the grounds should be checked. All equipment should be plugged into the Tripp Lite power strip (see photo below), and the Tripp Lite power strip should be plugged into the wall. If the output of the differential amplifier is unstable, verify that all E-6 equipment is plugged into the Tripp Lite power strip, which is located adjacent to the lab table (see photo below), and the Tripp Lite power strip is plugged into the wall.  No E-6 equipment should be plugged into the power strip on the back of the computer cart, which has a dubious ground (as of 3/10/14).
Line 38: Line 40:
[[attachment:TrippLite.png]] [[attachment:TrippLite.png|{{attachment:TrippLite.png|attachment:TrippLite.png|width="500 height=138"}}]]

E-6: Cathode Ray Oscilloscope And Differential Amplifier

Quantity: 39

attachment:E-6-200.jpg

Experiment Contents

Also
  • 1 Oscilloscope Manual

Check

  • Plug Board Kit (30 Items)

    • Resistor Set (100Ω, 200Ω, 400Ω, 1kΩ, 2.2kΩ, 3.3kΩ, 4.7kΩ, 10kΩ, 20kΩ, 100kΩ, 10MΩ)
    • 8 Bridge Plugs
    • Capacitor Set (47nF, 1μF, 0.47μF)
    • Diode
    • Inductor (1 H)
    • SPDT Switch
    • Variable Resistor (1k)
    • Transistor (2N1480)
    • Differential Amplifier
    • Adapter Set (2 Pomona 1269, 2 Pomona 1296, 1 BNC 'T')

Troubleshooting

If the output of the differential amplifier is unstable, verify that all E-6 equipment is plugged into the Tripp Lite power strip, which is located adjacent to the lab table (see photo below), and the Tripp Lite power strip is plugged into the wall. No E-6 equipment should be plugged into the power strip on the back of the computer cart, which has a dubious ground (as of 3/10/14).

attachment:TrippLite.png


200 Level Index

Home

il: E-206 (last edited 2018-06-04 18:51:12 by BrettUnks)