Size: 834
Comment:
|
Size: 1852
Comment:
|
Deletions are marked like this. | Additions are marked like this. |
Line 1: | Line 1: |
## page was renamed from E-6-200 | |
Line 4: | Line 5: |
=== E-6: Cathode Ray Oscilloscope And Differential Amplifier === | === E-6: Oscilloscopes and RC Decay === ==== Quantity: 39 ==== |
Line 7: | Line 9: |
[[attachment:E-6-200.png|{{attachment:E-6-200.jpg|attachment:E-6-200.jpg|width="500 height=138"}}]] |
|
Line 8: | Line 12: |
* 1 Oscilloscope * 1 Function Generator (Krohn-Hite, Pasco) * 1 Keithley 175 Digital Multimeter * 1 Plug Board * w/Kit * 1 UW Timer (Include Only If Using Krohn-Hite Type Function Generator) |
* 1 [[3323-1#Leader_Oscilloscope|Oscilloscope]] * w/ 2 [[Hanging Oscilloscope Probes#BNC_to_Alligator_Cables|Oscilloscope Probes]] * 1 [[3323-1#Kruhn-Hite_Function_Generators|Function Generator]] * 1 [[3323-2#FlukeMultimeter|Fluke 115 Handheld Multimeter]] * w/[[Hanging PASCO Voltage Sensors#Fluke_Multimeter_Sensor|Fluke Multimeter Probe Set]] * 2 [[3323-3#BNC_to_Alligator_Cables|BNC to Alligator Cable]] * 1 [[3323-10#Plug_Board|Plug Board]] * w/[[3323-9#Plug_Board_Kit|Kit]] |
Line 15: | Line 22: |
* 1 Oscilloscope Manuel | * 1 Oscilloscope Manual |
Line 17: | Line 25: |
* Plug Board Kit (29 Items) * Resistor Set (1kΩ, 2.2kΩ, 3.3kΩ, 4.7kΩ, 10kΩ, 20kΩ, 100kΩ, 10MΩ) |
* [[3323-9#Plug_Board_Kit|Plug Board Kit]] (30 Items) * Resistor Set (100Ω, 200Ω, 400Ω, 1kΩ, 2.2kΩ, 3.3kΩ, 4.7kΩ, 10kΩ, 20kΩ, 100kΩ, 10MΩ) |
Line 20: | Line 28: |
* Capacitor Set (47nf, 1μf) | * Capacitor Set (47nF, 1μF, 0.47μF) |
Line 22: | Line 30: |
* Inductor (1 Hy) | * Inductor (1 H) |
Line 28: | Line 36: |
=== Troubleshooting === If the output of the differential amplifier is unstable, verify that all E-6 equipment is plugged into the Tripp Lite power strip, which is located adjacent to the lab table (see photo below), and the Tripp Lite power strip is plugged into the wall. No E-6 equipment should be plugged into the power strip on the back of the computer cart, which has a dubious ground (as of 3/10/14). [[attachment:TrippLite.png|{{attachment:TrippLite.png|attachment:TrippLite.png|width="500 height=138"}}]] |
|
Line 30: | Line 44: |
[[Home]] |
E-6: Oscilloscopes and RC Decay
Quantity: 39
Experiment Contents
w/ 2 Oscilloscope Probes
w/Kit
Also
- 1 Oscilloscope Manual
Check
Plug Board Kit (30 Items)
- Resistor Set (100Ω, 200Ω, 400Ω, 1kΩ, 2.2kΩ, 3.3kΩ, 4.7kΩ, 10kΩ, 20kΩ, 100kΩ, 10MΩ)
- 8 Bridge Plugs
- Capacitor Set (47nF, 1μF, 0.47μF)
- Diode
- Inductor (1 H)
- SPDT Switch
- Variable Resistor (1k)
- Transistor (2N1480)
- Differential Amplifier
- Adapter Set (2 Pomona 1269, 2 Pomona 1296, 1 BNC 'T')
Troubleshooting
If the output of the differential amplifier is unstable, verify that all E-6 equipment is plugged into the Tripp Lite power strip, which is located adjacent to the lab table (see photo below), and the Tripp Lite power strip is plugged into the wall. No E-6 equipment should be plugged into the power strip on the back of the computer cart, which has a dubious ground (as of 3/10/14).