Differences between revisions 2 and 4 (spanning 2 versions)
Revision 2 as of 2013-06-13 19:04:54
Size: 1975
Editor: srnarf
Comment:
Revision 4 as of 2013-06-18 18:26:15
Size: 2856
Editor: srnarf
Comment:
Deletions are marked like this. Additions are marked like this.
Line 14: Line 14:
attachment: mainPhoto attachment:MITACgyro06-400.jpg
Line 23: Line 23:
||Weights||[:MechanicsCabinetBayA12: ME, Bay A12, Shelf #2]|| || ||Weights||[:MechanicsCabinetBayA12: ME, Bay A12, Shelf #1]|| ||
Line 27: Line 27:
 *  '''''One of the three of our MITAC gyroscopes does not allow the outer ring to rotate around the vertical axis.'''''  * '''''One of the three of our MITAC gyroscopes does not allow the outer ring to rotate around the vertical axis.'''''
 * '''''It takes a few seconds for the flywheel to get up to speed.'''''
Line 32: Line 33:
 1. List steps for setup then procedure.
 1. ...
 1. Place the MITAC gyroscope on the table and unlock all the retaining screws that hold the rings in place.
 1. Plug it in to a 110v outlet.
 1. Weights can be added to either end of the Axle "arrow" (ie. Axes of rotation)to show precession and nutation.
Line 43: Line 45:
||attachment: photo||attachment: photo||attachment: photo||attachment: photo|| ||attachment:MITACgyro01-250.jpg||attachment:MITACgyro02-250.jpg||attachment:MITACgyro03-250.jpg||attachment:MITACgyro04-250.jpg||
||attachment:MITACgyro05-250.jpg||attachment:MITACgyro07-250.jpg||attachment:MITACgyro08-250.jpg||attachment:MITACgyro09-250.jpg||
||attachment:MITACgyro10-250.jpg||attachment:MITACgyro11-250.jpg||attachment:MITACgyro12-250.jpg||attachment:MITACgyro13-250.jpg||
||attachment:MITACgyro14-250.jpg||attachment:MITACgyro15-250.jpg||attachment:MITACgyro16-250.jpg||attachment:MITACgyro17-250.jpg||
||attachment:MITACgyro18-250.jpg||attachment:MITACgyro19-250.jpg||attachment:MITACgyro20-250.jpg||attachment:precession_nutation-250.png||

[:PiraScheme#Mechanics: Table of Mechanics Demonstration]

[:MEEquipmentList: List of Mechanics Equipment & Supplies]

[:Demonstrations:Lecture Demonstrations]

MITAC Gyroscope, 1Q50.30

Topic and Concept:

Location:

attachment:MITACgyro06-400.jpg

Abstract:

A commercially built motorized gyro on a gimbal includes counterweights.

Equipment

Location

ID Number

MITAC Gyroscope

[:MechanicsCabinetBayA12: ME, Bay A12, Shelf #1]

Weights

[:MechanicsCabinetBayA12: ME, Bay A12, Shelf #1]

Important Setup Notes:

  • One of the three of our MITAC gyroscopes does not allow the outer ring to rotate around the vertical axis.

  • It takes a few seconds for the flywheel to get up to speed.

Setup and Procedure:

  1. Place the MITAC gyroscope on the table and unlock all the retaining screws that hold the rings in place.
  2. Plug it in to a 110v outlet.
  3. Weights can be added to either end of the Axle "arrow" (ie. Axes of rotation)to show precession and nutation.

Cautions, Warnings, or Safety Concerns:

  • Keep fingers away from the moving parts of the gyroscope while it is running.

Discussion:

Discuss the physics behind the demonstration, explaining some of the various steps of the demonstration when appropriate.

attachment:MITACgyro01-250.jpg

attachment:MITACgyro02-250.jpg

attachment:MITACgyro03-250.jpg

attachment:MITACgyro04-250.jpg

attachment:MITACgyro05-250.jpg

attachment:MITACgyro07-250.jpg

attachment:MITACgyro08-250.jpg

attachment:MITACgyro09-250.jpg

attachment:MITACgyro10-250.jpg

attachment:MITACgyro11-250.jpg

attachment:MITACgyro12-250.jpg

attachment:MITACgyro13-250.jpg

attachment:MITACgyro14-250.jpg

attachment:MITACgyro15-250.jpg

attachment:MITACgyro16-250.jpg

attachment:MITACgyro17-250.jpg

attachment:MITACgyro18-250.jpg

attachment:MITACgyro19-250.jpg

attachment:MITACgyro20-250.jpg

attachment:precession_nutation-250.png

Videos:

References:

[:Instructional:Home]

fw: MITAC_Gyro (last edited 2013-07-12 18:18:11 by localhost)