Differences between revisions 2 and 6 (spanning 4 versions)
Revision 2 as of 2008-04-23 22:03:34
Size: 444
Editor: reardon
Comment:
Revision 6 as of 2013-07-12 18:18:09
Size: 1014
Editor: localhost
Comment: converted to 1.6 markup
Deletions are marked like this. Additions are marked like this.
Line 1: Line 1:
#acl reardon:read,write,delete,revert,admin FacultyGroup:read,write All:read
Line 3: Line 4:
Bells located in [:ElectrostaticsCabinet:Electrostatics Cabinet], A2. Bells located in [[ElectrostaticsCabinet|Electrostatics Cabinet]], A2.
Line 5: Line 6:
Toepler-Holtz located in [:ElectrostaticsCabinet:Electrostatics Cabinet], A3. Toepler-Holtz located in [[ElectrostaticsCabinet|Electrostatics Cabinet]], A3.
Line 7: Line 8:
Connect bells to Toepler-Holtz. Discharge Toepler-Holtz generator: grasp insulating handles and put terminals (2cm diameter metal balls) in contact with each other.
Line 9: Line 10:
Crank Toepler-Holtz. Bells should start to ring. Connect bells to Toepler-Holtz.
Line 11: Line 12:
attachment:ElectrostaticBells5B1030.jpg Separate terminals by 5 cm.
Line 13: Line 14:
[:ElectricFieldsAndPotential:Electric Fields and Potential] Crank Toepler-Holtz generator (there should be no spark between terminals). Bells should start to ring.
Line 15: Line 16:
[:Demonstrations:Demonstrations] Discharge Toepler-Holtz generator--you will likely see a fat spark between the two terminals as you do this. Do not put your hands near the terminals before you discharge them--the spark from the Toepler-Holtz can be painful.
Line 17: Line 18:
[:Instructional:Home] {{attachment:ElectrostaticBells5B1030.jpg}}
{{attachment:ElectrostaticBellsCloseUp.jpg}}

[[ElectricFieldsAndPotential|Electric Fields and Potential]]

[[Demonstrations]]

[[Instructional|Home]]

Electrostatic Bells 5B10.30

Bells located in Electrostatics Cabinet, A2.

Toepler-Holtz located in Electrostatics Cabinet, A3.

Discharge Toepler-Holtz generator: grasp insulating handles and put terminals (2cm diameter metal balls) in contact with each other.

Connect bells to Toepler-Holtz.

Separate terminals by 5 cm.

Crank Toepler-Holtz generator (there should be no spark between terminals). Bells should start to ring.

Discharge Toepler-Holtz generator--you will likely see a fat spark between the two terminals as you do this. Do not put your hands near the terminals before you discharge them--the spark from the Toepler-Holtz can be painful.

ElectrostaticBells5B1030.jpg ElectrostaticBellsCloseUp.jpg

Electric Fields and Potential

Demonstrations

Home

fw: ElectrostaticBells (last edited 2013-07-12 18:18:09 by localhost)