Size: 15067
Comment:
|
Size: 15314
Comment:
|
Deletions are marked like this. | Additions are marked like this. |
Line 8: | Line 8: |
''''' Please note that these tables have not yet been edited to match the equipment that is available within the UW-Madison lecture demo lab. There maybe many items listed within these tables that we either "can not do" or have available.''''' |
DC Circuits
PIRA classification 5F
Grayed Demos are either not available or haven't been built yet |
Please note that these tables have not yet been edited to match the equipment that is available within the UW-Madison lecture demo lab. There maybe many items listed within these tables that we either "can not do" or have available.
5F10. Ohm's Law
PIRA # |
Demonstration Name |
Abstract |
5F10.05 |
charge density in circuits |
Two demonstrations: first, an electroscope is used to probe the charge density along a large resistance attached to a 5 KV supply, and second, an example where current is flowing through a resistance with no change in potential. |
5F10.10 |
Ohm's law |
Measure current and voltage in a simple circuit. Change the voltage or resistance. |
5F10.10 |
Ohm's Law |
An ammeter, voltmeter, rheostat, and battery pack are connected to demonstrate Ohm's law. |
5F10.10 |
Ohm's law |
A battery, rheostat, and meters in a circuit. |
5F10.10 |
Ohm's law |
Measure current and voltage in a simple circuit. |
5F10.10 |
Ohm's law |
Place 2, 4, and 6 V across a resistor and measure the current, then graph. |
5F10.12 |
water analogy circuit |
A water analogy illustrates voltage drops across a dc circuit. |
5F10.15 |
water Ohm's law analog |
|
5F10.15 |
water analog |
A water analog of Ohm's law. |
5F10.15 |
IR drop in a wire |
Clip wires from the terminals of flashlight lamps at various points along a stretched wire carrying 2 - 5 amps. |
5F10.20 |
potential drop along a wire |
Lecture galvanometers configured as a voltmeter and ammeter measure current and voltage on several samples of wire of the same length. A slide clip can be used to vary length. |
5F10.20 |
voltage drop along wire |
Measure the voltage at six points on a long resistance wire. |
5F10.25 |
potential drop with Wimshurst |
A 3 m long wood bar is attached at one end to one terminal of a static machine. The other end can be grounded or insulated. Attach several electroscopes along the bar to show flow of charge and potential drop. |
5F10.26 |
high voltage Ohm's law |
Two ends of a dry stick are attached to a static machine. Measure with an electrostatic voltmeter and microammeter. |
5F15. Power and Energy
PIRA # |
Demonstration Name |
Abstract |
5F15.10 |
electrical equivalent of heat |
Measure the voltage and current to a heating coil in a calorimeter. |
5F15.10 |
heat and electrical energy |
A heating coil in a calorimeter. |
5F15.10 |
electrical equvalent of heat |
Voltage, current to a heater and temperature rise in water are measured. |
5F15.10 |
electrocalorimeter |
Determine the power delivered by temperature change in water and compare to that computed from voltage, current, and time. |
5F15.11 |
flow calorimeter |
Water is heated electrically as it flows through a tube. |
5F15.12 |
heating by current from a static mot |
The ends of a piece of wood sealed in a glass tube are attached to a static machine. The half watt dissipated heats the air and an attached manometer measures the volume change. |
5F15.15 |
KWH meter and loads |
Measure the power consumed by an assortment of household appliances. |
5F15.16 |
heating with current |
Large currents are passed through No. 18 nichrome wire and the volts and amps are measured. |
5F15.17 |
heating wires in series |
Several lengths of different wires of the same length are soldered together in series and a piece of paper is hung from each by soft wax. As current is passed through the wire, the paper falls off at different times. |
5F15.20 |
hot dog cooker |
Hook nails to 110V and place them on and then in a hot dog. |
5F15.20 |
hot dog frying |
Apply 110 V through a hot dog and cook it. |
5F15.30 |
fuse with 30v lamp |
|
5F15.31 |
fuse-wire problem |
With fuse wires of different diameters connected in parallel, which will burn out first? |
5F15.32 |
vaporize wire with 500 amp surge |
Short a low voltage high current transformer with zinc coated iron wire. |
5F15.33 |
fuse wire |
Fuse wire is used with a miniature house circuit. |
5F15.34 |
fuses |
Fuse wire of different sizes are connected across a heavy copper buss. |
5F15.35 |
fuse with increasing load |
|
5F15.40 |
voltage drops in house wires |
Two resistance wires substituting for house wiring glow when they power a load of lamps and heaters. |
5F15.45 |
I2R losses |
Copper and nichrome wires in series show different amounts of heating due to current. A paper rider on the nichrome wire burns. |
5F20. Circuit Analysis
PIRA # |
Demonstration Name |
Abstract |
5F20.10 |
Kirchoff's voltage law |
Measure the voltages around a three resistor and battery circuit. |
5F20.10 |
Kirchoff's voltage law |
Measure the voltages around a three resistor and battery circuit. |
5F20.10 |
sum of IR drops |
Measure the voltages across three resistors and a battery in a series circuit. |
5F20.13 |
voltage divider |
A simple series circuit of a battery and two resistors. |
5F20.15 |
continuity of current |
Same as Eo-4. |
5F20.15 |
continuity of current |
An ammeter can be inserted into any branch of a circuit to show currents in and out of a node. |
5F20.16 |
conservation of current |
Measure the currents entering and leaving a node. |
5F20.20 |
superposition of current |
Same as Eo-7. |
5F20.20 |
superposition of currents |
Measure the current from one battery, a second in another position, and the combination in a circuit. |
5F20.20 |
superposition |
Shows a standard superposition circuit. |
5F20.25 |
reciprocity |
Shows a standard reciprocity circuit. |
5F20.30 |
potentiometer |
A slide wire potentiometer is used with a battery and demonstration galvanometer. |
5F20.30 |
potentiometer |
A slide wire potentiometer with a standard cell. |
5F20.31 |
rheostat as potential divider |
Contrast the slide wire rheostat when used as a rheostat or potential divider. |
5F20.32 |
long potentiometer |
Use a ten foot length of nichrome wire as a slide wire potentiometer. |
5F20.33 |
rheostat potential divider |
A rheostat and six volt battery demonstrate a potential divider. |
5F20.40 |
wheatstone bridge - slide wire |
The slide wire Wheatstone bridge. |
5F20.40 |
wheatstone bridge - slide wire |
Two nichrome wires are stretched across the lecture bench and sliding clips connected to a galvanometer are used to find equal potential points. |
5F20.41 |
wheatstone bridge - human galvan. |
Stretch a loop of close line previously soaked in salt solution in a parallelogram and hook the ends to a 110 V line. Touch two points of the same potential without shock. |
5F20.42 |
wheatstone bridge |
A demonstration Wheatstone bridge with a built in meter and several plug in resistors. |
5F20.45 |
lightbulb wheatstone bridge |
A Wheatstone bridge configuration with lightbulbs for resistors. |
5F20.45 |
light bulb wheatstone bridge |
Four light bulbs in a Wheatstone bridge arrangement with light bulb indicator. |
5F20.45 |
light bulb wheatstone bridge |
A light bulb Wheatstone bridge using 110 ac. |
5F20.45 |
wheatstone bridge |
Four 60 W lamps in a diamond bridge with a 10 W lamp as the indicator. An additional 6 V lamp can be switched in when the circuit is balanced. |
5F20.45 |
wheatstone bridge |
Three 110 V lamps and a rheostat make up the diamond of a Wheatstone bridge and a small lamp serves as an indicator. |
5F20.50 |
series and parallel light bulbs |
A light bulb board with switches allows configuration of several combinations of series and parallel lamps. |
5F20.50 |
series and parallel light bulbs |
A light bulb board with switches allows configuration of several combinations. |
5F20.50 |
parallel and series light bulbs |
Three similar wattage lamps in series, three in parallel. |
5F20.50 |
series-parallel circuits |
A series-parallel circuit with three bulbs and six switches can be connected 14 ways. |
5F20.50 |
series/parallel light bulbs |
Three 110 V lamps are wired in series and three are wired in parallel. |
5F20.51 |
light bulb board - 12 V |
A board with 12V bulbs and a car battery allow combinations of up to three series or three parallel loads. |
5F20.55 |
series/parallel resistors |
Measure the current flowing through a wire resistor with 6 V applied and then series and parallel combinations. |
5F20.56 |
wire combinations |
A wire circuit is arranged so a segment of n length can have 1 or n wires in parallel. Drawing. |
5F20.60 |
equivalent series resistance |
A series of resistors in a circuit are replaced by a single resistor. |
5F20.61 |
parallel resistance - integral value |
A formula for obtaining integral values of resistors in parallel to obtain an integral equivalent resistance. |
5F20.61 |
equivalent parallel resistance |
Parallel resistors are replaced by a single resistor in a circuit. |
5F20.63 |
Thevenin's equivalent resistance |
A Wheatstone bridge resistance circuit is used to reduce resistor combinations to an equivalent resistance. |
5F20.64 |
equivalent circuit flasher |
A neon flasher circuit shows the combination rules for series and parallel combinations of resistance and capacitance by timing light flashes. |
5F20.71 |
large circuit boards |
A modular circuit board made for 500 student auditoriums. |
5F20.72 |
general circuits board |
A circuit board laid out so meters can be plugged in and readings taken for demonstrations of series-parallel circuits and Kirchhoff's laws. |
5F20.75 |
three-way switch |
A large circuit board demonstrates a three way switch. |
5F20.79 |
one boar, river, six people |
An electrical circuit for solving the problem of getting across the river. |
5F20.95 |
equivalent resistance analog comput. |
Using the equivalent resistance of a circuit as an analog computer for finding the focal length of an optical problem. |
= 5F30. RC Circuits =
PIRA # |
Demonstration Name |
Abstract |
5F30.10 |
capacitor and light bulb |
A large lelectrolytic capacitor, a light bulb, and a 120 V dc supply in series show a long time constant. |
5F30.10 |
capacitor and light bulb |
A 5600 microF capacitor is charged and discharged through 7.5 and 40 W light bulbs. |
5F30.10 |
long RC time constant |
A 5600 microF capacitor, a light bulb, and a 120 V dc supply in series show a long time constant where the bulb dims as the capacitor charges. |
5F30.11 |
light the bulb |
Charge a capacitor with DC and discharge through a light bulb, try the same thing with AC. |
5F30.12 |
discharge a capacitor |
Discharge a capacitor through a resistor. Read the voltage with a meter. |
5F30.15 |
RC time constant on galvanometer |
A series RC circuit with a galvanometer. Diagram. |
5F30.16 |
RC voltage follower |
Use a voltage follower to isolate the circuit from the display. |
5F30.20 |
RC time constant on scope |
A circuit with a slow time constant (.1 - 10 sec.) is charged and discharged and the current and voltage are displayed on a dual trace storage scope. |
5F30.20 |
RC charging curve |
Show charging and discharging a RC circuit with a battery on an oscilloscope. |
5F30.21 |
RC time constant |
Show the time constant from an RC circuit on an oscilloscope. |
5F30.21 |
RC time constant |
A plug in circuit board for showing RC time constants on the oscilloscope. |
5F30.22 |
time constant of an capacitive cir. |
The time constant of a RC circuit driven by the calibration signal is shown on an oscilloscope. |
5F30.28 |
finding R from time constant |
A circuit to measure high resistances by using an RC charging time. |
5F30.50 |
series and parallel capacitors |
Two 2 microF capacitors in series or parallel with a 40 W lamp. |
5F30.60 |
neon relaxation oscillator |
|
5F30.60 |
blinking neon bulb |
A neon bulb in parallel with a capacitor will light periodically as the capacitor charges and discharges. |
5F30.60 |
RC relaxation oscillator |
An RC relaxation oscillator has a neon lamp across the capacitor provide a visible discharge. |
5F30.60 |
RC flasher circuit |
A neon lamp in parallel with the capacitor in a series RC circuit. |
5F30.60 |
flashing neon light |
A battery powered neon light oscillator. |
5F30.60 |
neon relaxation oscillator |
A circuit for a neon relaxation oscillation oscillator. Reference: AJP 13(12),415. |
5F30.60 |
relaxation oscillator |
An RC neon light relaxation oscillator. |
5F30.61 |
relaxation siren oscillator |
A double RC relaxation oscillator with slow and fast periods gives a siren waveform. |
5F30.68 |
backward and forward waves |
RC circuits are used to get a wave in neon bulbs that goes from the sink to the source. |
5F30.71 |
capacitance operated relay |
References but no information on the circuit. Bring your hand close to a aluminum plate and the relay triggers. |
5F30.80 |
fun circuit |
One box has switches that control two lights in another box but only one wire connects the two boxes. |
5F40. Instruments
PIRA # |
Demonstration Name |
Abstract |
5F40.10 |
sensitivity and resistance of a galv |
A circuit for the determination of galvanometric constants. |
5F40.10 |
sensitivity and resistance of galvan |
Use external resistors to measure the resistance and sensitivity of a galvanometer. |
5F40.15 |
voltmeter and electroscope |
Connect series resistance to a galvanometer to make a voltmeter with low sensitivity and measure several dry batteries in series with both the voltmeter and an electroscope. |
5F40.20 |
converting a galvanometer to a voltm |
Knowing the resistance and sensitivity of a galvanometer, add a series resistance and check with a voltage. |
5F40.20 |
galvanometer as voltmeter and ammete |
A galvanometer is used with shunt and series resistors. |
5F40.21 |
loading by a voltmeter |
Measure the voltage across a high resistance circuit with high and low impedance voltmeters. |
5F40.25 |
converting a galvanometer to a ammet |
Knowing the resistance and sensitivity of a galvanometer, add a shunt resistance and measure a current. |
5F40.30 |
hot wire ammeter |
A crude hot wire galvanometer. |
5F40.30 |
hot wire ammeter |
Diagram of a hot wire ammeter. (E-171). |
5F40.35 |
iron vane meter |
Repulsion from induced magnetism in two soft iron bars in a solenoid forms the basis of a heavy current ammeter. |
5F40.50 |
multimeters |
A couple multimeters are pictured. |
[:Demonstrations:Demonstrations]
[:Instructional:Home]