| Located in [:ElectrostaticsCabinet:ElectrostaticsCabinet], A2 | Precipitator located in [:ElectrostaticsCabinet:ElectrostaticsCabinet], A2 Toepler-Holtz generator located in [:ElectrostaticsCabinet:ElectrostaticsCabinet], A3 | 
| Line 7: | Line 10: | 
| Connect the electrodes at the end of the tube to a Wimshurst generator. | Discharge Toepler-Holtz generator: grasp insulating handles and put terminals (2cm diameter metal balls) in contact with each other. Connect the electrodes at the end of the tube to the Toepler-Holtz generator. Separate the terminals of the Toepler-Holtz by 5 cm. | 
| Line 11: | Line 18: | 
| Crank the generator and the smoke clears ("precipitates"). | Crank the generator (there should be no sparking between the terminals). The smoke should clear ("precipitate"). | 
| Line 13: | Line 20: | 
| [:ElectricityAndMagnetism: Electricity & Magnetism] | Discharge Toepler-Holtz generator--you will likely see a fat spark between the two terminals as you do this. Do not put your hands near the terminals before you discharge them--the spark from the Toepler-Holtz can be painful. attachment:CottrellPrecipitator5B3060.jpg [:ElectricFieldsAndPotential: Electric Fields and Potential] | 
Cottrell Precipitator 5B30.60
Precipitator located in [:ElectrostaticsCabinet:ElectrostaticsCabinet], A2
Toepler-Holtz generator located in [:ElectrostaticsCabinet:ElectrostaticsCabinet], A3
Light a cone of incense and place the incense in the precipitator.
Discharge Toepler-Holtz generator: grasp insulating handles and put terminals (2cm diameter metal balls) in contact with each other.
Connect the electrodes at the end of the tube to the Toepler-Holtz generator.
Separate the terminals of the Toepler-Holtz by 5 cm.
Wait until the tube fills with smoke.
Crank the generator (there should be no sparking between the terminals). The smoke should clear ("precipitate").
Discharge Toepler-Holtz generator--you will likely see a fat spark between the two terminals as you do this. Do not put your hands near the terminals before you discharge them--the spark from the Toepler-Holtz can be painful.