Precipitator located in [:ElectrostaticsCabinet:ElectrostaticsCabinet], A2
Line 4: Line 6:
Light a cone of incense and place the incense in the tube. Toepler-Holtz generator located in [:ElectrostaticsCabinet:ElectrostaticsCabinet], A3
Line 6: Line 8:
Connect the electrodes at the end of the tube to a Wimshurst generator. Light a cone of incense and place the incense in the precipitator.

Discharge Toepler-Holtz generator: grasp insulating handles and put terminals (2cm diameter metal balls) in contact with each other.

Connect the electrodes at the end of the tube to the Toepler-Holtz generator.

Separate the terminals of the Toepler-Holtz by 5 cm.
Line 10: Line 18:
Crank the generator and the smoke clears ("precipitates"). Crank the generator (there should be no sparking between the terminals). The smoke should clear ("precipitate").
Line 12: Line 20:
[:ElectrostaticsCabinet:ElectrostaticsCabinet] Discharge Toepler-Holtz generator--you will likely see a fat spark between the two terminals as you do this. Do not put your hands near the terminals before you discharge them--the spark from the Toepler-Holtz can be painful.
Line 14: Line 22:
[:ElectricityAndMagnetism: Electricity & Magnetism] attachment:CottrellPrecipitator5B3060.jpg

[:ElectricFieldsAndPotential: Electric Fields and Potential]

Cottrell Precipitator 5B30.60

Precipitator located in [:ElectrostaticsCabinet:ElectrostaticsCabinet], A2

Toepler-Holtz generator located in [:ElectrostaticsCabinet:ElectrostaticsCabinet], A3

Light a cone of incense and place the incense in the precipitator.

Discharge Toepler-Holtz generator: grasp insulating handles and put terminals (2cm diameter metal balls) in contact with each other.

Connect the electrodes at the end of the tube to the Toepler-Holtz generator.

Separate the terminals of the Toepler-Holtz by 5 cm.

Wait until the tube fills with smoke.

Crank the generator (there should be no sparking between the terminals). The smoke should clear ("precipitate").

Discharge Toepler-Holtz generator--you will likely see a fat spark between the two terminals as you do this. Do not put your hands near the terminals before you discharge them--the spark from the Toepler-Holtz can be painful.

attachment:CottrellPrecipitator5B3060.jpg