Size: 445
Comment:
|
Size: 1103
Comment:
|
Deletions are marked like this. | Additions are marked like this. |
Line 3: | Line 3: |
Precipitator located in [:ElectrostaticsCabinet:ElectrostaticsCabinet], A2 | |
Line 4: | Line 5: |
Light a cone of incense and place the incense in the tube. | Toepler-Holtz generator located in [:ElectrostaticsCabinet:ElectrostaticsCabinet], A3 |
Line 6: | Line 7: |
Connect the electrodes at the end of the tube to a Wimshurst generator. | Light a cone of incense and place the incense in the precipitator. Discharge Toepler-Holtz generator: grasp insulating handles and put terminals (2cm diameter metal balls) in contact with each other. Connect the electrodes at the end of the tube to the Toepler-Holtz generator. Separate the terminals of the Toepler-Holtz by 5 cm. |
Line 10: | Line 17: |
Crank the generator and the smoke clears ("precipitates"). | Crank the generator (there should be no sparking between the terminals). The smoke should clear ("precipitate"). |
Line 12: | Line 19: |
[:ElectrostaticsCabinet:ElectrostaticsCabinet] | Discharge Toepler-Holtz generator--you will likely see a fat spark between the two terminals as you do this. Do not put your hands near the terminals before you discharge them--the spark from the Toepler-Holtz can be painful. |
Line 14: | Line 21: |
[:ElectricityAndMagnetism: Electricity & Magnetism] | attachment:CottrellPrecipitator5B3060.jpg [:ElectricFieldsAndPotential: Electric Fields and Potential] |
Cottrell Precipitator 5B30.60
Precipitator located in [:ElectrostaticsCabinet:ElectrostaticsCabinet], A2
Toepler-Holtz generator located in [:ElectrostaticsCabinet:ElectrostaticsCabinet], A3
Light a cone of incense and place the incense in the precipitator.
Discharge Toepler-Holtz generator: grasp insulating handles and put terminals (2cm diameter metal balls) in contact with each other.
Connect the electrodes at the end of the tube to the Toepler-Holtz generator.
Separate the terminals of the Toepler-Holtz by 5 cm.
Wait until the tube fills with smoke.
Crank the generator (there should be no sparking between the terminals). The smoke should clear ("precipitate").
Discharge Toepler-Holtz generator--you will likely see a fat spark between the two terminals as you do this. Do not put your hands near the terminals before you discharge them--the spark from the Toepler-Holtz can be painful.
attachment:CottrellPrecipitator5B3060.jpg
[:ElectricFieldsAndPotential: Electric Fields and Potential]
[:Demonstrations:Demonstrations]
[:Instructional:Home]